Parameters for F:\Projects\MedChem\KellyLee\Sally\18Feb2020_NA.PRO\ACQUDB\mobileHDX_15min_DRE.EXP
Created by 4.2 SCN1003
 
Lock Spray Configuration:
Reference Scan Frequency(sec)			60.000
Reference Cone Voltage(V)			40.000
Reference Trap Collision Energy			21.000
Reference DRE Setting				99.900
 
Temperature Correction:
Temperature Correction				Disabled
 
Instrument Configuration:
Lteff						1800.0
Veff						7199.20
Resolution					20000
Min Points in Peak				2
Acquisition Device				WatersADC
Acquisition Algorithm				ADC Mode
ADC Trigger Threshold (V)			1.00
ADC Input Offset (V)				-1.50
Average Single Ion Intensity			30
ADC Amplitude Threshold				3
ADC Centroid Threshold				-1
ADC Ion Area Threshold				3
ADC Ion Area Offset				10
ADC Pushes Per IMS Increment			1
EDC Delay Coefficient				1.3500
EDC Delay Offset				0.4000
 
Experimental Instrument Parameters
Instrument Parameter Filename			F:\Projects\MedChem\KellyLee\Sally\18Feb2020_NA.PRO\ACQUDB\HDX_70_130_Accurate_HDX_2018_3.IPR (MODIFIED)
Polarity					ES+
Capillary (kV)					2.5000
Source Temperature (°C)				70
Sampling Cone					40.0000
Source Offset					50.0000
Source Gas Flow (mL/min)			0.00
Desolvation Temperature (°C)			130
Cone Gas Flow (L/Hr)				80.0
Desolvation Gas Flow (L/Hr)			600.0
Nebuliser Gas Flow (Bar)			6.5
LM Resolution					4.0
HM Resolution					15.0
Aperture 1					0.0
Pre-filter					2.0
Ion Energy					1.0
Manual Trap Collision Energy			FALSE
Trap Collision Energy				4.0
Manual Transfer Collision Energy		FALSE
Transfer Collision Energy			2.0
Manual Gas Control				FALSE
Trap Gas Flow (mL/min)				2.00
HeliumCellGasFlow				180.00
IMS Gas Flow (mL/min)				90.00
Detector					2400
DetectorCache					2150
Sample Infusion Flow Rate (µL/min)		20
Sample Flow State				LC
Sample Fill Volume (µL)				250
Sample Reservoir				Wash
LockSpray Infusion Flow Rate (µL/min)		20
LockSpray Flow State				Infusion
LockSpray Reservoir				B
LockSpray Capillary (kV)			2.0
Use Manual LockSpray Collision Energy		FALSE
Collision Energy				4.0
Acceleration1					67.0
Acceleration2					200.0
Aperture2					70.0
Transport1					70.0
Transport2					70.0
Steering					1.02
Tube Lens					74
Pusher						1889.0
Pusher Offset					-0.38
Puller						1361.0
Pusher Cycle Time (µs)				Automatic
Pusher Width (µs)				Automatic
Collector					60
Collector Pulse					10.0
Stopper						10
Stopper Pulse					20.0
Entrance					62
Static Offset					180
Puller Offset					-0.00
Reflectron Grid (kV)				1.478
Flight Tube (kV)				10.00
Reflectron (kV)					3.780
Use Manual Trap DC				TRUE
Trap DC Entrance				3.0
Trap DC Bias					45.0
Trap DC						0.0
Trap DC Exit					3.0
Use Manual IMS DC				TRUE
IMS DC Entrance					20.0
Helium Cell DC					50.0
Helium Exit					-20.0
IMSBias						3.0
IMS DC Exit					0.0
USe Manual Transfer DC				TRUE
Transfer DC Entrance				4.0
Transfer DC Exit				15.0
Trap Manual Control				OFF
Trap Wave Velocity (m/s)			311
Trap Wave Height (V)				4.0
IMS Manual Control				ON
IMS Wave Velocity (m/s)				650
IMS Wave Height (V)				35.0
Transfer Manual Control				ON
Transfer Wave Velocity (m/s)			380
Transfer Wave Height (V)			4.0
Step Wave 1 In Manual Control			ON
Enable Reverse Operation			OFF
Step Wave 1 In Velocity (m/s)			300.0
Step Wave 1 In Height				10.0
Step Wave 1 Out Manual Control			ON
Step Wave 1 Out Velocity (m/s)			300.0
Step Wave 1 Out Height				0.0
Step Wave 2 Manual Control			ON
Step Wave 2 Velocity (m/s)			300.0
Step Wave 2 Height				0.0
Use Manual Step Wave DC				ON
Step Wave TransferOffset			10.0
Step Wave DiffAperture1				0.0
Step Wave DiffAperture2				0.0
Use Automatic RF Settings			FALSE
StepWave1RFOffset				100.0
StepWave2RFOffset				100.0
Target Enhancement Enabled			FALSE
Target Enhancement Mode				EDC
Target Enhancement Mass				556.0
Target Enhancement Trap Height (V)		12.0
Target Enhancement Extract Height (V)		8.0
Mobility Trapping Manual Release Enabled	FALSE
Mobility Trapping Release Time (µs)		500
Mobility Trap Height (V)			15.0
Mobility Extract Height (V)			0.0
Trag Gate LUT table enabled			FALSE
TriWave Trap Gate LookUp Table			
Using Drift Time Trimming			TRUE
Drift Time Bins					0
Using Mobility Delay after Trap Release		TRUE
IMS Wave Delay (µs)				1000
Variable Wave Height Enabled			FALSE
Wave Height Ramp Type				Linear
Wave Height Start (V)				10.0
Wave Height End (V)				40.0
Wave Height Using Full IMS			TRUE
Wave Height Ramp (%)				100.0
Wave Height Look Up Table			
Variable Wave Velocity Enabled			TRUE
Wave Velocity Ramp Type				Linear
Wave Velocity Start (m/s)			600.0
Wave Velocity End (m/s)				1000.0
Wave Velocity Using Full IMS			TRUE
Wave Velocity Ramp (%)				100.0
Wave Velocity Look Up Table			
Backing						3.31e0
Source						9.00e-3
Sample Plate					1.00e-6
Trap						2.71e-2
Helium Cell					4.59e0
IMS						3.00e0
Transfer					2.81e-2
TOF						7.41e-7
IMSRFOffset					300
IMSMobilityRFOffset				250
TrapRFOffset					300
Use Automatic RF Settings			FALSE
AutoStepWave1RFOffset				150
AutoStepWave2RFOffset				150
TransferRFOffset				350
MS Profile Type					Auto P
MSProfileMass1					100
MSProfileDwellTime1				20
MSProfileRampTime1				20
MSProfileMass2					300
MSProfileDwellTime2				20
MSProfileRampTime2				40
MSProfileMass3					500
PusherInterval					69.000000
PusherOffset					0.250000
LockMassValidSigma				5
 
Acquisition mass range
Start mass					150.000
End mass					2000.000
Calibration mass range
Start mass					91.062
End mass					1925.941
 
Experiment Reference Compound Name: Leucine Enkephalin
 
Function Parameters - Function 1 - MOBILITY MS FUNCTION
Scan Time (sec)					2.000
Interscan Time (sec)				0.015
Start Mass					150.0
End Mass					2000.0
Start Time (mins)				3.44
End Time (mins)					19.00
Data Format					Continuum
Analyser					Resolution Mode
ADC Sample Frequency (GHz)			3.0
ADC Pusher Frequency (µs)			69.0
ADC Pusher Width (µs)				1.75
Use Tune Page Cone Voltage			YES
Using Auto Trap Collision Energy (eV)		4.000000
Using Auto Transfer Collision Energy (eV)	2.000000
Sensitivity					Normal
Dynamic Range					Normal
Save Collapsed Retention Time Data		No
Use Rule File Filtering				No
FragmentationMode				CID
Calibration					Dynamic 2
 
Function Parameters - Function 2 - REFERENCE
Scan Time (sec)					1.000
Interscan Time (sec)				0.100
Start Mass					150.0
End Mass					2000.0
Start Time (mins)				3.44
End Time (mins)					19.00
Data Format					Continuum
Analyser					Resolution Mode
ADC Sample Frequency (GHz)			3.0
ADC Pusher Frequency (µs)			69.0
ADC Pusher Width (µs)				1.75
Use Tune Page Cone Voltage			YES
Using Auto Trap Collision Energy (eV)		4.000000
Using Auto Transfer Collision Energy (eV)	2.000000
Sensitivity					Normal
Dynamic Range					Normal
Save Collapsed Retention Time Data		No
Use Rule File Filtering				No
FragmentationMode				CID
[LOCK SPRAY]
LockSprayType:					Do not apply correction
LockSpray Reference Compound Name:		Leucine Enkephalin
Scan Time (sec)					1.00
Interval					60
EDC Mass					0.0000
Mass Window +/-					0.4
Scans to Average				1.0
Reference Cone Voltage				40.0
Trap Collision Energy (eV)			21.0
LocksprayDRESetting				99.9000
[METHOD EVENTS:]
Timed Events Enabled:				YES
API Probe Delay Temp:				20.0
Num of Timed Events:				5.0
Event	Time	Name	Action				System
1	-60.00	Flow State	LC				Sample
2	-60.00	Reservoir	B				LockSpray
3	-60.00	Refill	Auto-Refill			LockSpray
4	-60.00	Infusion	Start				LockSpray
5	60000.00	Infusion	Stop			LockSpray


Calibration					Dynamic 2
 