Parameters for E:\projects AG Kammerer\Simon\Simon.PRO\ACQUDB\20180808_NuclIMS.EXP
Created by 4.1 SCN916
 
Lock Spray Configuration:
Reference Scan Frequency(sec)			30.000
Reference Cone Voltage(V)			40.000
Reference Trap Collision Energy			4.000
Reference DRE Setting				99.900
 
Temperature Correction:
Temperature Correction				Disabled
 
Instrument Configuration:
Lteff						1800.0
Veff						7195.30
Resolution					20000
Min Points in Peak				2
Acquisition Device				WatersADC
Acquisition Algorithm				ADC Mode
ADC Trigger Threshold (V)			0.90
ADC Input Offset (V)				-1.59
Average Single Ion Intensity			33
ADC Amplitude Threshold				3
ADC Centroid Threshold				-1
ADC Ion Area Threshold				4
ADC Ion Area Offset				10
ADC Pushes Per IMS Increment			1
EDC Delay Coefficient				1.3500
EDC Delay Offset				0.4000
 
Experimental Instrument Parameters
Instrument Parameter Filename			E:\projects AG Kammerer\Simon\Simon.PRO\ACQUDB\Nucleoside_IMS_opti.IPR (MODIFIED)
Polarity					ES+
Capillary (kV)					2.5000
Source Temperature (°C)				110
Sampling Cone					20.0000
Source Offset					20.0000
Source Gas Flow (mL/min)			0.00
Desolvation Temperature (°C)			600
Cone Gas Flow (L/Hr)				40.0
Desolvation Gas Flow (L/Hr)			1200.0
Nebuliser Gas Flow (Bar)			6.0
LM Resolution					10.0
HM Resolution					15.0
Aperture 1					0.0
Pre-filter					2.0
Ion Energy					1.0
Manual Trap Collision Energy			TRUE
Trap Collision Energy				4.0
Manual Transfer Collision Energy		TRUE
Transfer Collision Energy			2.0
Manual Gas Control				TRUE
Trap Gas Flow (mL/min)				0.40
HeliumCellGasFlow				180.00
IMS Gas Flow (mL/min)				70.00
Detector					2925
DetectorCache					0
Sample Infusion Flow Rate (µL/min)		5
Sample Flow State				LC
Sample Fill Volume (µL)				250
Sample Reservoir				A
LockSpray Infusion Flow Rate (µL/min)		5
LockSpray Flow State				Infusion
LockSpray Reservoir				B
LockSpray Capillary (kV)			1.5
Use Manual LockSpray Collision Energy		FALSE
Collision Energy				4.0
Acceleration1					70.0
Acceleration2					200.0
Aperture2					70.0
Transport1					70.0
Transport2					70.0
Steering					0.00
Tube Lens					70
Pusher						1900.0
Pusher Offset					-0.40
Puller						1370.0
Pusher Cycle Time (µs)				Automatic
Pusher Width (µs)				Automatic
Collector					50
Collector Pulse					10.0
Stopper						10
Stopper Pulse					20.0
Entrance					62
Static Offset					180
Puller Offset					0.00
Reflectron Grid (kV)				1.470
Flight Tube (kV)				10.00
Reflectron (kV)					3.780
Use Manual Trap DC				TRUE
Trap DC Entrance				3.0
Trap DC Bias					45.0
Trap DC						0.0
Trap DC Exit					3.0
Use Manual IMS DC				TRUE
IMS DC Entrance					35.0
Helium Cell DC					35.0
Helium Exit					-5.0
IMSBias						3.0
IMS DC Exit					0.0
USe Manual Transfer DC				TRUE
Transfer DC Entrance				4.0
Transfer DC Exit				15.0
Trap Manual Control				OFF
Trap Wave Velocity (m/s)			300
Trap Wave Height (V)				6.0
IMS Manual Control				ON
IMS Wave Velocity (m/s)				650
IMS Wave Height (V)				30.0
Transfer Manual Control				ON
Transfer Wave Velocity (m/s)			315
Transfer Wave Height (V)			4.0
Step Wave 1 In Manual Control			OFF
Enable Reverse Operation			OFF
Step Wave 1 In Velocity (m/s)			300.0
Step Wave 1 In Height				10.0
Step Wave 1 Out Manual Control			OFF
Step Wave 1 Out Velocity (m/s)			300.0
Step Wave 1 Out Height				0.0
Step Wave 2 Manual Control			OFF
Step Wave 2 Velocity (m/s)			300.0
Step Wave 2 Height				0.0
Use Manual Step Wave DC				ON
Step Wave TransferOffset			10.0
Step Wave DiffAperture1				3.0
Step Wave DiffAperture2				0.0
Use Automatic RF Settings			FALSE
StepWave1RFOffset				80.0
StepWave2RFOffset				350.0
Target Enhancement Enabled			FALSE
Target Enhancement Mode				EDC
Target Enhancement Mass				556.0
Target Enhancement Trap Height (V)		12.0
Target Enhancement Extract Height (V)		8.0
Mobility Trapping Manual Release Enabled	FALSE
Mobility Trapping Release Time (µs)		500
Mobility Trap Height (V)			20.0
Mobility Extract Height (V)			0.0
Trag Gate LUT table enabled			FALSE
TriWave Trap Gate LookUp Table			
Using Drift Time Trimming			FALSE
Drift Time Bins					0
Using Mobility Delay after Trap Release		FALSE
IMS Wave Delay (µs)				1000
Variable Wave Height Enabled			FALSE
Wave Height Ramp Type				Linear
Wave Height Start (V)				17.0
Wave Height End (V)				35.0
Wave Height Using Full IMS			TRUE
Wave Height Ramp (%)				50.0
Wave Height Look Up Table			
Variable Wave Velocity Enabled			FALSE
Wave Velocity Ramp Type				Linear
Wave Velocity Start (m/s)			1000.0
Wave Velocity End (m/s)				400.0
Wave Velocity Using Full IMS			TRUE
Wave Velocity Ramp (%)				50.0
Wave Velocity Look Up Table			
Backing						3.01e0
Source						7.38e-3
Sample Plate					1.00e-6
Trap						1.58e-2
Helium Cell					3.07e0
IMS						2.65e0
Transfer					1.77e-2
TOF						4.14e-7
IMSRFOffset					300
IMSMobilityRFOffset				150
TrapRFOffset					300
Use Automatic RF Settings			FALSE
AutoStepWave1RFOffset				300
AutoStepWave2RFOffset				350
TransferRFOffset				350
MS Profile Type					Auto P
MSProfileMass1					100
MSProfileDwellTime1				20
MSProfileRampTime1				20
MSProfileMass2					300
MSProfileDwellTime2				20
MSProfileRampTime2				40
MSProfileMass3					500
PusherInterval					39.000000
PusherOffset					0.250000
LockMassValidSigma				5
 
Acquisition mass range
Start mass					50.000
End mass					600.000
Calibration mass range
Start mass					90.996
End mass					1178.607
 
Experiment Reference Compound Name: LeuEnk_SP_Res_pos
 
Function Parameters - Function 1 - MOBILITY MS FUNCTION
Scan Time (sec)					0.500
Interscan Time (sec)				0.014
Start Mass					50.0
End Mass					600.0
Start Time (mins)				0.00
End Time (mins)					12.00
Data Format					Continuum
Analyser					Resolution Mode
ADC Sample Frequency (GHz)			3.0
ADC Pusher Frequency (µs)			39.0
ADC Pusher Width (µs)				1.00
Use Tune Page Cone Voltage			YES
Using Auto Trap Collision Energy (eV)		4.000000
Using Auto Transfer Collision Energy (eV)	2.000000
Sensitivity					Normal
Dynamic Range					Normal
Save Collapsed Retention Time Data		Yes
Use Rule File Filtering				No
FragmentationMode				CID
Calibration					Dynamic 2
 
Function Parameters - Function 2 - MOBILITY MS FUNCTION
Scan Time (sec)					0.500
Interscan Time (sec)				0.014
Start Mass					50.0
End Mass					600.0
Start Time (mins)				0.00
End Time (mins)					12.00
Data Format					Continuum
Analyser					Resolution Mode
ADC Sample Frequency (GHz)			3.0
ADC Pusher Frequency (µs)			39.0
ADC Pusher Width (µs)				1.00
Use Tune Page Cone Voltage			YES
Using Auto Trap Collision Energy (eV)		4.000000
Use Auto Transfer Collision Energy		NO
Transfer Collision Energy Ramp Start (eV)	20.0
Transfer Collision Energy Ramp End (eV)		50.0
Sensitivity					Normal
Dynamic Range					Normal
Save Collapsed Retention Time Data		Yes
Use Rule File Filtering				No
FragmentationMode				CID
Calibration					Dynamic 2
 
Function Parameters - Function 3 - REFERENCE
Scan Time (sec)					0.000
Interscan Time (sec)				0.100
Start Mass					50.0
End Mass					600.0
Start Time (mins)				0.00
End Time (mins)					12.00
Data Format					Continuum
Analyser					Resolution Mode
ADC Sample Frequency (GHz)			3.0
ADC Pusher Frequency (µs)			39.0
ADC Pusher Width (µs)				1.00
Use Tune Page Cone Voltage			YES
Using Auto Trap Collision Energy (eV)		4.000000
Using Auto Transfer Collision Energy (eV)	2.000000
Sensitivity					Normal
Dynamic Range					Normal
Save Collapsed Retention Time Data		Yes
Use Rule File Filtering				No
FragmentationMode				CID
[LOCK SPRAY]
LockSprayType:					Do not apply correction
LockSpray Reference Compound Name:		LeuEnk_SP_Res_pos
Scan Time (sec)					0.00
Interval					30
EDC Mass					0.0000
Mass Window +/-					0.5
Scans to Average				3.0
Reference Cone Voltage				40.0
Trap Collision Energy (eV)			4.0
LocksprayDRESetting				99.9000
[METHOD EVENTS:]
Timed Events Enabled:				YES
API Probe Delay Temp:				20.0
Num of Timed Events:				4.0
Event	Time	Name	Action				System
1	-60.00	Flow State	LC				Sample
2	-60.00	Reservoir	B				LockSpray
3	-60.00	Refill	Auto-Refill			LockSpray
4	-60.00	Infusion	Start				LockSpray


Calibration					Dynamic 2
 